GENERAL INFORMATION
TECHNICAL INFORMATION
PUBLICATIONS
CONTACTING US
QUOTE REQUEST







THE WORLD CHAMPION RE-ROOFING SYSTEM Site Content (c) 2008 Roof Hugger, Inc.


ROOF HUGGER ENGINEERING AND TECHNICAL INFORMATION

 

FLORIDA PRODUCT APPROVED
INSTALLATION GUIDE

 

Click PDF for an Adobe PDF file for viewing or click CAD for downloading a CAD file


PDF AutoCAD

SYSTEM 1:
FLORIDA PRODUCT APPROVAL # 9561.1, 10141.0

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “PBR” panel 12” o.c. rib spacing, 26 or 24 gauge.
New Roof Panel Attachment: 1- #12–14 Tek-3 WeatherGuard fastener every 12” (12”-12”-12”…) into sub-purlins, Lap Fasteners ¼”–14, 20” o.c.
Roof Hugger Sub- Purlin Spacing: 5’-0” o.c. (Eave and every purlin line)
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin.

SYSTEM 1 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
L / 120
L / 180
L / 240
26
40.00
40.00
38.00
24
35.00
31.44
26.42

 

PDF AutoCAD

SYSTEM 2:
FLORIDA PRODUCT APPROVAL # 9561.1, 10141.0

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “PBR” panel 12” o.c. rib spacing, 26 or 24 gauge.
New Roof Panel Attachment: 2 - #12-14 Tek-3.
WeatherGuard fastener every 12” (7”-5”-7”-5”-7”…) into sub-purlins, Lap Fasteners ¼”–14, 20” o.c.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line).
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin.

SYSTEM 2 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
L / 120
L / 180
L / 240
26
65.00
45.00
33.80
24
60.00
60.44
58.14

 

PDF AutoCAD

SYSTEM 3:
FLORIDA PRODUCT APPROVAL # 9561.1, 10141.0

 

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “PBR” panel 12” o.c. rib spacing, 26 or 24 gauge.
New Roof Panel Attachment: 2- #12–14 Tek-3 WeatherGuard fastener every 12” (7”-5”-7”-5”-7”…) into sub-purlins, Lap Fasteners Ό”–14, 20” o.c. Sub-Rafter Spacing: 2’-0” o.c.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line). 2’-6” o.c. or less over sub-rafters between primary purlins.
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin, 2- Ό”-14 Tek-3 into sub-rafter (1 each side of major ribs), 2-#17 into existing roof panel (1 each side of major ribs) and 1- #10 Pancake Head fastener 2’o.c. connecting Hugger to sub-rafter.

SYSTEM 3 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
L / 120
L / 180
L / 240
26
110.00
110.00
110.00
24
116.00
111.77
85.14

 

PDF AutoCAD

SYSTEM 4:
FLORIDA PRODUCT APPROVAL # 9561.1, 10141.0

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “PBR” panel 12” o.c. rib spacing, 26 or 24 gauge.
New Roof Panel Attachment: 2- #12–14 Tek-3 WeatherGuard fastener every 12” (7”-5”-7”-5”-7”…) into sub-purlins, Lap Fasteners Ό”–14, 20” o.c. Sub-Rafter Spacing: 1’-0” o.c.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line). 2’-6” o.c. or less over sub-rafters between primary purlins.
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin, 2- Ό”-14 Tek-3 into sub-rafter (1 each side of major ribs) and 1- #10 Pancake Head fastener 1’o.c. connecting Hugger to sub-rafter.

SYSTEM 4 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
L / 120
L / 180
L / 240
26
140.00
140.00
116.17
24
145.00
120.41
92.24

 

PDF AutoCAD

SYSTEM 5:
FLORIDA PRODUCT APPROVAL # 9352.1

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “200 DL” Standing Seam panel, 18” o.c. Rib spacing, 24 gauge, as Manufactured by Architectural Building Components, Houston, TX.
New Roof Panel Attachment: 2- #1/4–14 Tek-3 Fasteners into sub-purlins spaced 5’-0” o.c. Sub-Rafter Spacing: None.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line).
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin.

SYSTEM 5 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
Purlin Space
Max. Load PSF
24
5'-0"
40.00

 

PDF AutoCAD

SYSTEM 6:
FLORIDA PRODUCT APPROVAL # 9352.1

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “200 DL” Standing Seam panel, 18” o.c. Rib spacing, 24 gauge, as Manufactured by Architectural Building Components, Houston, TX.
New Roof Panel Attachment: 2- #1/4–14 Tek-3 Fasteners into sub-purlins spaced 5’-0” o.c. Sub-Rafter Spacing: 2’-0” o.c.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line). 2’-6” o.c. over sub-rafters between primary purlins.
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin, 2- Ό”-14 Tek-3 into sub-rafter (1 each side of major ribs), 2-#17 into existing roof panel (1 each side of major ribs) and 1- #10 Pancake Head fastener 2’o.c. connecting Hugger to sub-rafter.

SYSTEM 6 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
Purlin Space
Max. Load PSF
24
2'-6"
80.00

 

PDF AutoCAD

SYSTEM 7:
FLORIDA PRODUCT APPROVAL # 9352.1

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “200 DL” Standing Seam panel, 18” o.c. Rib spacing, 24 gauge, as Manufactured by Architectural Building Components, Houston, TX.
New Roof Panel Attachment: 2- #1/4–14 Tek-3 Fasteners into sub-purlins spaced 5’-0” o.c. Sub-Rafter Spacing: 2’-0” o.c.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line). 1’-3” o.c. over sub-rafters between primary purlins.
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin, 2- Ό”-14 Tek-3 into sub-rafter (1 each side of major ribs), 2-#17 into existing roof panel (1 each side of major ribs) and 1- #10 Pancake Head fastener 2’o.c. connecting Hugger to sub-rafter.

SYSTEM 7 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
Purlin Space
Max. Load PSF
24
1'-3"
90.00

 

PDF AutoCAD

SYSTEM 8:
FLORIDA PRODUCT APPROVAL # 9352.2

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “SuperLok”, 16” o.c. Rib spacing, 24 gauge, as Manufactured by MBCI, Houston, TX.
New Roof Panel Attachment: 2- #1/4–14 Tek-3 Fasteners into sub-purlins spaced 5’-0” o.c. Sub-Rafter Spacing: None.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line).
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin.

SYSTEM 8 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
Purlin Space
Max. Load PSF
24
5'-0"
47.50

 

PDF AutoCAD

SYSTEM 9:
FLORIDA PRODUCT APPROVAL # 9352.2

Existing Roof Panel: “R” panel (26, 24, 22 ga.)
New Roof Panel: “SuperLok”, 16” o.c. Rib spacing, 24 gauge, as Manufactured by MBCI, Houston, TX.
New Roof Panel Attachment: 2- #1/4–14 Tek-3 Fasteners into sub-purlins spaced 5’-0” o.c. Sub-Rafter Spacing: 2’-0” o.c.
Roof Hugger Sub-Purlin Spacing: 5’-0” o.c. (Eave and every purlin line). 2’-6” o.c. over sub-rafters between primary purlins.
Roof Hugger Attachment: 2- #12–14 Tek-3 fasteners per L.F. into existing purlin, 2- Ό”-14 Tek-3 into sub-rafter (1 each side of major ribs), 2-#17 into existing roof panel (1 each side of major ribs) and 1- #10 Pancake Head fastener 2’o.c. connecting Hugger to sub-rafter.

SYSTEM 9 - ALLOWABLE DESIGN PRESSURES (-PSF)
FACTOR OF SAFETY 2.0

Panel Ga.
Purlin Space
Max. Load PSF
24
2'-6"
80.00
Mailing Address: P.O. Box 1027, Odessa, FL 33556 Shipping Address: 144-B Whitaker Road, Lutz, FL 33549